PRE-WIRED LOOP INSTALLATION
ON
SL-150
Model
SL-150
IMPORTANT:
provides two pre-wired loop harnesses one for SAFETY LOOP and one for EXIT
LOOP. Loop detectors must be 120 VAC.
To install loop detectors make sure power is off in main power source then simply plug detector
in designated harness socket and wire the ground loop to the grey and brown wires located
inside the electrical box behind operator gearbox. There is one pair labeled EXIT for EXIT LOOP
and one pair labeled SAFETY for SAFETY LOOP.
Use different frequencies for every loop detector.
IMPORTANT: When useing the safety loop, you must remove the jumper from “SAF LOOP” on
terminal strip.