beautypg.com

Important, 3 - control box installation, 2 - actuator installation – Controlled Products Systems Group 1550ETL-1K User Manual

Page 8

background image

8

Figure 5 - APOLLO 816-1K LIMIT SWITCH AND SMART SENSOR WIRING

Apollo 816-1K

operator

green

orange

white

yellow

blue

1.4 - Apollo 816-1K limit switch and smart sensor wiring

Connect the Apollo 816-1K

actuator cable to the 5-pin

connector as shown in Figure

5. These connections enable

the Apollo 816-1K limit switch

and smart sensor inputs into

the gate controller.

Note: Connector is keyed.

Install connector in keyed

orientation

white:

close limit switch

orange: open limit switch
green: limit switch and motor encoder common
yellow: motor encoder signal
blue:

motor encoder power (+12VDC)

1.3 - Control Box Installation

Mount the control box within 4 feet of the pivot arm. Do not
mount the control box where the person using the push
button on side of the box can come in contact with the
gate.
Use mounting hardware capable of supporting the
weight of the control box with the battery installed.
Mounting holes are not provided since mounting surfaces will
vary.

Set battery inside of control box with terminals toward the
front (Do not use any battery with side terminals).

IMPORTANT

Never weld parts to the gate or posts when the operator circuit board is powered. Doing so may
damage the board beyond repair.

1/2” x 3 1/2” Hex Bolt

1/2” Washer

1/2” Lock Nut

Do not over tighten Nut and Bolt

1.2 - Actuator Installation

Figure 3: Actuator Installation

Figure 4: Box Installation

This manual is related to the following products: