beautypg.com

5 - funcɵon (conɵnued) – Controlled Products Systems Group 1550ETL-1K User Manual

Page 26

background image

26

11.5 - FuncƟon (ConƟnued)

Advance Settings:
The following settings are available for customizing the gate operator as required by the customer’s instal-
lation requirements:

x

Set Language (English, Spanish, Italian)

x

Set clock 12H/24H

x

Set LCD Contrast

x

Direction of the Motor (only selectable in learning mode)

x

Auto Close Opt. (ON - Gate only closes when at open limit, OFF - Gate auto-closes from any open po-
sition)

x

Exit Opt. (ON - Free Exit always opens gate, OFF - Free Exit doesn't open gate if stopped while open-
ing)

x

Set Anti-tailgate (Closes gate immediately after vehicle has cleared safety sensors)

x

Phototest (activates monitoring feature for BlueBus photoeyes)

x

Select inputs LOOP or PHOTO

x

Select UL/EDGE input type (NO, NC, Analog)

x

Select Master / Slave Motor1 or Motor2

x

Activate link for remote Master/Slave (Enables control of an additional gate operator board - Not Appli-
cable in this installation)

x

Power Fail Open (Opens gate automatically on batter backup power if main AC power input loss is de-
tected) (Not Applicable in this installation)

x

Motor 12V (Forces motor control voltage to +12VDC even if the supply voltage varies from +9.5VDC
up to +35VDC)

x

Set Virtual Encoder (Used for motors without built-in encoders)


Default: This setting gives the installer/user the option of returning some or all
settings of the gate operator to the original factory settings:
• System settings
• Radio Channel settings
• Event settings
• Charger settings

ESC: Exit the FUNCTION menu.

This manual is related to the following products: