11

PUSH TO OPEN INSTALLATION

Both measurements are
taken from the center of the
hinge.

11”

6”

Direction of opening

Gate (closed)

Hinge post

Top View

Vertical position of
pivot arm (s)

Pivot arm must be
level

1/2”

Hinge

Center Line of attachment
point for gate bracket

Front View

Location of pivot point

2.1 - PIVOT ARM(s) INSTALLATION

2.2 - REWIRING ACTUATOR TO PUSH OPEN

Apollo

816-1K

Red and Black

motor power

Note - If gate moves in opposite
direction from what is expected,
reverse the motor power lead wir-
ing. (Red to pin 3, Black to pin 1)

Red

black

Apollo

816-1K

operator

green

orange

white

yellow

blue

white:

close limit switch

orange: open limit switch
green: limit switch and motor encoder common
yellow: motor encoder signal
blue:

motor encoder power (+12VDC)