beautypg.com

Aintenance – Controlled Products Systems Group 10463283 User Manual

Page 34

background image

M

AINTENANCE

P a g e 3 4

Ja nua ry , 2 00 7

6 2 0 /6 40 O pera tor And

6 2 4B LD C ontr ol Pa ne l Ins tal la tion M a nual

R

EGULAR

M

AINTENANCE

Inspect and service your 620 or 640 Barrier system

anytime you observe or suspect a malfunction of the

barrier. In addition, FAAC recommends you check the

barrier system every 1,000,000 cycles of the operator for

the items listed below to keep your operator in the best

working condition. Failure to observe these

recommendations could compromise the functionality of

the operator.

Item to Check Every

1,000,000 Cycles

What to Do

Entire barrier system

Replace any visually

obvious defective part

Oil level

Refill the oil if necessary

Bypass valves

Tighten or loosen the

valves to maintain the

recommended pressure

settings

Beam motion

Adjust the compression

spring if necessary

Cooling fan

Clean the motor cooling

ducts

Control panel

Test the function of input

power and output function

of all attached relays, cards,

and devices

S

PECIAL

M

AINTENANCE

Inspect and service your 620 or 640 Barrier system

anytime you observe or suspect a malfunction of the

barrier. In addition, if your observations warrant it,

FAAC recommends you make the following listed repairs

and replacements to the barrier system to keep your

operator in the best working condition. Failure to

observe these recommendations could compromise the

functionality of the operator.

Part(s) to Repair or Replace

Number of

Cycles

Drive pistons:

seals and gaskets

1,000,000

Ball joints in the rocker arm

1,000,000

Mechanical stops

1,000,000

Hydraulic unit:

seals and gaskets

2,000,000

Cooling fan

2,000,000

Balancing spring

3,000,000

Limit switches

6,000,000