2ND LEVEL PROGRAMMING

To access 2nd LEVEL PROGRAMMING, press push-

button F and, while holding it down, press push-
button “+”.

If you release the push-button “+”, the display
shows the name of the first function.

If you also release the F push-button, the display
shows the value or parameter of that function,

which can be changed with the “+” and”—” keys.

If you press the F key again (and hold it down),
the display shows the name of the next function,

etc.

When you reach the last function, press the F
push-button to exit programming, and the

display resumes showing the input status.

The following table indicates the sequence of

functions accessible in 2nd LEVEL PROGRAMMING.

P a g e 2 9

Ja nua ry , 2 00 7

6 2 0 /6 40 O pera t or A nd
6 2 4B LD C ontr ol Pa ne l Ins talla tio n M a nual

T

HE

624 BLD C

O

N

TRO

L

P

AN
E

L

I

NS
TA
LLA

T

ION

I

NS
TRUC

TIO

N

S

2ND LEVEL PROGRAMMING

DISPLAY FUNCTION DEFAULT

MAXIMUM TORQUE AT THRUST:

The motor works at maximum

torque (ignoring the torque

adjustment) during the initial

time of the movement.

= Active

= Excluded

PRE-FLASHING:

To activate the flashing light for

5 sec before the start of the

movement

Excluded

Before every movement

Before closing

At end of pause only

SLOW

CLOSING:

For setting the entire closing

stage at slow speed.

= Active

= Excluded

DECELERATION

TIME

AFTER

LIMIT-SWITCHES:

For setting deceleration time (in

seconds) after the opening and

closing limit-switches have been

activated. It can be adjusted from

0 to 10 sec, in one second steps.

= deceleration excluded

= maximum deceleration

WORK TIME (time out):

We advise you to set a value from

5 to 10 seconds longer than the

required by the automated

system to move from the closing

to the opening position and vice

versa. It can be adjusted from 0

to 59 sec in one second steps.

Next, the viewing changes in

minutes and tenths of a second

(separated by a dot) and time is

adjusted in 10 second steps, up

to the maximum value of 4.1

minutes.