beautypg.com

Chapin 22190XP User Manual

Warning, Pre-use check 4. filling, Care, storage and maintenance

background image

WARNING!

3. Pre-Use Check

4. Filling

1) Do: Turn pump handle counterclockwise and remove pump

2) Do: Prepare spray solution following all directions and safety warnings on chemical label.

3) Do: Fill tank to no more than the proper gallon marker. Do NOT: over fill to accommodate pump.

4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and tighten securely.

9. Care, Storage and Maintenance

010538-8 (A) R0412

WARNING:

Handling the brass parts of this product will expose you to lead, a chemical known

to the State of California to cause birth defects and other reproductive harm. Wash hands after

handling.

2. Nozzle

6-6136

Hose

Manguera

Tuyau

6-1898

Shut-off Handle

Mango de cierre

Poignée du robinet

6-3337

Straps

Tirantes

Sangles

For constant spraying, push down on shut-off

handle and move locking mechanism away from

you. To release, squeeze handle and move the

locking mechanism back towards you.

6. Fatigue-Free Spraying

Note:

Your particular sprayer may not include all parts pictured above.

Nota:

Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.

Remarque :

Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.

Attach nozzle to shut-off handle or extension wand.

Parts, Piezas, Pièces

6-6141

Hose Brown

Manguera Castaño

Tuyau Brun

6-5943

Nozzle 1.0 GPM

Tobera

Buse

6-7734

Extension wand,

Vara de extensión, Rallonge

6-5797

Nozzle .5GPM

Tobera

Buse

6-7749

Extension wand,

Vara de extensión, Rallonge

6-4638

Shut-off Handle

Mango de cierre

Poignée du robinet

6-6003

Nozzle

Tobera

Buse

6-000

Nozzle

Tobera

Buse

3-7727

Extension wand,

Vara de extensión, Rallonge

Repair Parts Kit Gaskets and Seals (not included),

Juego de piezas de reparación, empaquetaduras y juntas (no incluido)

Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus) 6-4601

6A

Locking

mechanism

6B

2A

2B

1. Hose to Tank

Discharge/ Assembly

• Make sure white outlet tube is attached to outlet tube adapter (Fig. 1A).

• Insert the outlet tube portion of the discharge assembly into the tank adapter (Fig. 1B).

• Proper placement of white outlet tube (Fig. 1C).

• Firmly insert the outlet tube adapter into the tank adapter (Fig. 1D) Lining up tab with notches on the tank adapter.

• Firmly tighten the retaining nut to the tank adapter (Fig. 1E).

Discharge

Assembly

1B

Outlet

Tube

1E

Retaining Nut -

Securely tightened.

1C

1D

No

Gap

Tank

Adapter

Outlet Tube

Adapter

Tab/

Notch

1A

Outlet Tube

Adapter

Outlet

Tube

Sk-1154-1

WARNING: Improper use or failure to follow instructions can result in explosive failure causing serious

eye or other injury.

For safe use of this product you must read and follow all instructions. Do not leave a pres-

surized sprayer in the hot sun. Heat can cause pressure build-up resulting in possible explosion. Do not store or

leave solution in tank after use. Always wear goggles, gloves, long sleeve shirt, long pants and full foot protec-

tion when spraying. Never use any tool to remove pump if there is pressure in sprayer. Never stand with face or

body over top of tank when pumping or loosening pump to prevent ejecting pump assembly and/or solution

from striking and injuring you. Never pressurize sprayer by any means other than the original pump. Do not

attempt to modify this sprayer. Replace parts only with manufacturer’s original parts. Never spray flammable,

caustic, acidic, chlorine, bleach or other corrosive solutions or heat, pressure, or gas producing chemicals.

Always read and follow chemical manufacturer’s instructions before use with this sprayer as some chemi-

cals may be hazardous when used with this sprayer.

1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.

2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are found, replace hose

before using. Replace with original manufacturer’s parts only.

3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and exterior of tank for signs

of deterioration of body and bottom. Any sign of deterioration indicates possible tank weakening and could result in

explosive bursting under pressure. If any of these signs are found, discard tank immediately and replace. Do not

attempt to patch leaks, etc., as this could result in serious injury.

4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only (Pump plunger 10-20 strokes and

inspect for leaks).

5) Do: Direct shut-off away from you and open to make sure discharge is not clogged.

6) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank, and proceed with Filling,

Pressurizing and Spraying Instructions.

7) Do: Inspect all metal parts including the wand, nozzle and fittings for rust, corrosion and pitting. If any of these

conditions are found, replace affected part with original manufacturer’s part before using.

1) Do: Rinse tank thoroughly with water only, empty, refill with water. Follow Filling, Pressurizing and Spraying

Instructions, except pump unit only 8-10 strokes. Be sure that the wand and nozzle are thoroughly rinsed with

water after each use.

2) Do: Open shut-off and allow water to run through discharge assembly.

3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer.

4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.

5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening in cover.

6-4605

Pressure Relief Valve

Válvula de descarga de presión

Soupape de décompression

6. Pressurizing and Spraying

Do:

Turn handle clockwise to

tighten. Push handle down,

turn 1/4 turn counterclock-

wise to release.

Do:

Pump until you

feel resistance.

Do:

Push handle, down, turn

1/4 turn clockwise to lock. Begin

spraying. Re-pump sprayer as

required to maintain spray force.

6A

6C

6B

7. To Release Pressure

1) Your sprayer is equipped with a pressure relief/release valve

(Fig. 7A). To release pressure lift and hold the cap until air

is completely exhausted, OR, turn the valve slowly counter

clockwise until you hear air escaping and wait air is completely

exhausted (Fig. 7B).

2) Do: Stay away from the sprayer until all air has escaped.

7A

7B

8. Wand Dock Clip

Choose the holder that fits your wand.

10. Troubleshooting

-

Tank pressurizes but does not spray.

WARNING: Release pressure in tank before troubleshooting.

Clean Nozzle Assembly (Fig. 10E) -Remove nozzle cap by unscrewing. Clean and re-assemble.

Clean shut-off (Fig. 10A- 10D)

10E

Nozzle Cap

Pull handle straight

up.

Insert notches from

underside of handle

into plunger grooves

and turn counter-

clockwise.

Tighten plunger clockwise until

flush to top of shut-off body. Do

not over-tighten or unit may not

spray. Slide forks under plunger,

push handle down until it snaps

into place.

10A

10B

Handle

10D

Plunger flush

with body

Remove plunger, diaphragm and

spring. Wash diaphragm with

mild detergent. Reassemble:

Hold shut-off upright as shown,

place spring in hole, place

diaphragm on top of spring.

Reassemble plunger and tighten.

10C

Plunger

Spring

Diaphragm