beautypg.com

Unlinking an insteon responder from i/o linc – INSTEON I/O Linc (2450) Manual User Manual

Page 6

background image

Page 6 of 16

NOTE: During linking, you will have the option to turn on remote INSTEON devices when either the connected sensor is closed or
when it is opened. Once this is programmed, the opposite action will trigger an OFF command. For example, if you program an
ON command to be sent when the I/O Linc connected sensor is closed, opening the sensor will trigger an OFF command.

1) Put your sensor into the state you want to use to trigger I/O Linc to send an ON command. For example, if you want closing

the sensor to send an ON command, close the sensor.

The Sensor Status LED

will

turn on if the sensor is closed and off if the sensor is open

2) Set I/O Linc to linking mode by pressing & holding the Set button until it beeps (3 seconds)

The I/O Linc Status LED

will

begin blinking

You will have 4 minutes to complete the next step before linking mode automatically times out.

3) Press & hold the Responder’s Set button for 3 seconds

The I/O Linc Status LED

will

stop blinking and turn on solid

4) Confirm that linking was successful by tapping the Set button on I/O Linc

The responder

will

respond appropriately

Unlinking an INSTEON Responder from I/O Linc

1) If the responder is a multi-scene device, tap the Scene button you wish to remove control from until its LED

illuminates

2) Set I/O Linc to linking mode by pressing & holding the Set button until it beeps ( 3 seconds)

The I/O Linc Status LED will begin blinking

3) Set I/O Linc to unlinking mode by pressing & holding the Set button until it beeps again (3 seconds)

The I/O Linc Status LED will continue blinking

You will have 4 minutes to complete the next step before unlinking mode automatically times out.

2477D