Synchronized Scene with 4 members (3-way/4-way)

Software is recommended, however, the following steps, when carefully followed, will also work.
For our example we will Synchronize SwitchLincs and identify them as switches A, B, C and D.

1)

Turn all switches on – to the desired (and same) Scene level

a. Press & hold Switch A’s Set button until it beeps (or LED blinks)

Switch A’s LED will blink

b. Tap Switch A’s Set button

Switch A’s LED will continue blinking

c. For switches B, C and D, press & hold the Set button on each, one at a time, until it

double-beeps (or LED flashes)

Switch B, C and D will (Beep)-(Beep) and its LED will flash once

d. Tap Switch A’s Set button

Switches B, C, and D are now Responders of and Synchronized to switch A’s
setting as a Scene Controller

2)

Return to Step 1 above, turn all switches on – to the desired (and same) Scene level

3)

Follow steps a. and b. above substituting with switch B to start Synchronized Scenes

4)

Follow step c. for switches A, C and D

5)

Follow step d. above substituting with switch B to end program

6)

Return to Step 1 above, turn all switches on – to the desired (and same) Scene level

7)

Follow steps a. and b. above substituting with switch C to start Synchronized Scenes

8)

Follow step c. for switches A, B and D

9)

Follow step d. above substituting with switch C to end program

10)

Return to Step 1 above, turn all switches on – to the desired (and same) Scene level

11)

Follow steps a. and b. above substituting with switch D to start Synchronized Scenes

12)

Follow step c. for switches A, B and C

13)

Follow step d. above substituting with switch D to end program


All 4 switches are now set as Scene Controllers and each of the remaining switches in the group are
Synchronized as Responders

Air Gap

To remove all power from SwitchLinc and connected light(s), pull the Set button at the bottom of the
switch out as far as it will go, about 1/8”. (It might be helpful to use a small screwdriver.) This will open
mechanical contacts creating an Air Gap.

To restore power, tap the air gap back into place, until its top is even with the trim frame.

Note: If you press Set button in too far, you might inadvertently reset the INSTEON device to its factory
default settings. Make sure to only push the Set button down so that it is flush with trim frame.

Factory Reset

Factory Reset clears all user settings from SwitchLinc including INSTEON Scenes, On-Levels, Ramp
Rates, X10 addresses, etc.

1)

Pull Set button out (creating an Air Gap)

2)

Wait 10 Seconds

3) Press the Set Button in as far as you can & hold

SwitchLinc will (Beep)

4) Release the Set button

Device’s embedded software will re-write all settings to factory defaults
A couple of seconds will pass
SwitchLinc will (Beep)-(Beep)
LEDs will return to normal brightness
SwitchLinc returns to Ready Mode
Connected load will turn on