Clear-Com Communication Systems

Eclipse Matrix Installation Instruction Manual

4 - 3 2

WIRING AN ICS PANEL MISCELLANEOUS
CONNECTOR

Most local devices connect with a matrix panel via the “miscellaneous”
connector.

The following sections discuss how to wire the various functions
available on the “miscellaneous” connector.

• External program feed input

• Binaural headset (All Panels Except ICS-2003/2110/1016)

• Logic input #1 and logic input #2

• Mute relay contacts

• Auxiliary relay contacts.

Figure 4-23: Miscellaneous Connector Pin Configuration

EXTERNAL PROGRAM FEED INPUT

The external program feed input allows the panel operator to monitor
audio from an external source while simultaneously monitoring the
intercom audio.

The input is designed to accept a balanced, line-level audio feed at a
maximum level of 0 dB. On some panels there is no “program” volume
control. This is just a summing input to the “listen” amplifier.

The program feed input passes through the panel’s “program” volume
control before being mixed with the audio at the panel. The “program”

1

2

15

14

13

12

11

10

9

8

7

6

5

4

3

+ Program Input

- Program Input

Audio Ground

Second Ear Ground (Audio Ground in ICS-2003/ICS-2110)

Second Ear Output (Audio Ground in ICS-2003/ICS-2110)

Logic Ground

Logic Ground

Logic Input #1

Logic Input #2

Mute Relay Normally Closed

Station Relay Normally Closed

Mute Relay Wipe

Station Relay Wipe

Mute Relay Normally Open

Station Relay Normally Open

This manual is related to the following products: