Note: If the GP-OUT port is used the following filter must be fitted
between the PROC-RCC socket and the cable: CINCH
FA-25PS/1 25W D-type in-line 1000pF filter (UK supplier:
Farnell 111-4108).
Each general-purpose output has a relay inside the Eclipse
Omega/Median frame. When a general-purpose output is inactive, the
associated “common” pin on the GP OUT connector will be shorted to
the relevant “normally closed” pin. When a general-purpose output
becomes active, the short between the “common” pin is broken and a
new connection is made between the “common” pin and the “normally
open” pin.
Figure 4-6 shows the pin configuration of the general-purpose outputs
connector.
Figure 4-6: General-Purpose Outputs Connector Pinout
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Digital Ground
PIN
DESCRIPTION
1
2
3
4
RELAY 1 Common
RELAY 1 Normally Closed
RELAY 1 Normally Open
RELAY 2 Common
RELAY 2 Normally Closed
RELAY 2 Normally Open
RELAY 3 Common
RELAY 3 Normally Closed
RELAY 3 Normally Open
30 VDC at 1 Ampere
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
Normally Closed
RELAY 1
RELAY 2
RELAY 3
RELAY 4
RELAY 5
RELAY 6
RELAY 7
RELAY 8
RELAY 4 Common
RELAY 4 Normally Closed
RELAY 4 Normally Open
GROUND
RELAY 5 Common
RELAY 5 Normally Closed
RELAY 5 Normally Open
RELAY 6 Common
RELAY 6 Normally Closed
5
6
7
8
9
10
11
12
13
14
16
17
18
19
20
21
22
23
24
25
15
RELAY 6 Normally Open
RELAY 7 Common
RELAY 7 Normally Closed
RELAY 7 Normally Open
RELAY 8 Common
RELAY 8 Normally Closed
RELAY 8 Normally Open
DB-25 Male Connector