19. When satisfied with position of leveling valve and linkage has been checked
for proper operation and clearance, mark hole location to attach leveling valve
bracket to crossmember. Drill (2) 1/4” holes and install (2) 5/16” self tapping
bolts to attach bracket to crossmember.

Torque bolts to 10 ft-lb

6097 ( R-6097)