13. Prepare leveling valve for installation. The inlet and exhaust ports have a
screen across the base of the port while the delivery ports to the air springs have a
hole. See photos. Attach fittings to leveling valve as shown below. Torque fit-
tings to 7-8 ft-lb. Do not overtighten.

Inlet/Exhaust Port

Delivery Port

3/8” tube –1/4” MPT
elbow

3/8” tube—1/4”
MPT connector

6097 ( R-6097)