CHAPTER 3 - OPERATION
FLUID COMPONENTS INTL
Doc. No. 06EN003291 Rev. A
3 - 7
Model ST98 Flow Meter
Example:
Pressing [E] [ENTER] will always display “2.0 ma - 1k ohm”.
COMMAND:
F. K-Factor
Summary:
Permits the user to enter a K-Factor.
Description:
If the user determines that the flow rate output should be “biased”, a user supplied K-Factor can be applied to
modify the final flow reading from the calibrated flow rate.
Example:
Pressing [F] [ENTER] will display “K.F. = 1.0000000” on line 1 and "Change it?<" on line 2. Pressing [N]
[ENTER] will display "Input mode?<". Pressing [Y] [ENTER] will display "Enter K.F.#". Press in the new
K-Factor. Press [ENTER]. The new factor is saved and “Input mode ?<” is displayed.
COMMAND:
G. EEPROM
Summary:
For maintenance only. A passcode must be entered.
Description:
EEPROM byte locations can be read or modified.
Example:
N/A
COMMAND:
H. Heater
Summary:
Permits the user to toggle the heater circuit OFF and ON.
Description:
Useful whenever the heater needs to be turned off and on manually, i.e., while balancing the flow element or
trouble shooting the instrument.
Example:
Pressing [H] [ENTER] will display “Heater OFF!” or “Heater ON!” on line 1 depending on which state was
last active. “Input mode ?<” is displayed on line 2.