Burkert Type 8056 User Manual
Page 6

SE56
6
TECHNICAL CHARACTERISTICS
ENVIRONMENTAL USE CONDITIONS
The transmitter can be installed internally or externally
Altitude: from –200m to 2000m (from -656 to 6560 feet)
Humidity range: 0-85% without condensation
OPERATING TEMPERATURE
Consider the operating temperatures more restrictive between transmitter and sensor
* For discontinuous use, a thermostat heat source installation may be necessary.
Data plate
On the data plate there is some technical information:
•
MODEL: Transmitter Model
•
S/N: Serial Number of the transmitter
•
SUPPLY: Main power supply
•
Hz: Supply frequency (AC)
•
POWER: Maximum power consumption
•
IP: Protection grade
•
T: Operating temperature
•
COUPLING: Serial number of sensor coupled
•
ITEM: free for user
Min. *
Max
°C
-10
50
°F
14
122
ELECTRIC CHARACTERISTICS
Transmitter classification: class I, IP65, installation category (overvoltage) II, rated
pollution degree 2.
Power supply
versions
Power supply
voltage
Power supply
frequency
Max
power
HV
100-240V~
44-66Hz
6W
LV
18-45V
//
18-45V~
44-66Hz
Voltage changes must not exceed ±10% of the nominal one.
Input/output insulated up to 500V.
The output 4-20mA (optional) is electrically connected to the ON/OFF outputs and
the output power supply (24V
).