Burkert Type 8056 User Manual
Page 25

SE56
25
where fs
max
is the maximum full scale value corresponding to the sensor, equal to a 10m/s liquid
speed. The measure units are shown as appear on the display. The British and American units are
diversified by using capital and small characters.
When a mass measure unit is set, the specific gravity function is automatically enabled by the
system. Please, note that the mass measure is heavily affected by the temperature. With certain
liquids this may cause significant measurement errors. The following time measure units can be
selected: s = second, m = minute, h = hour, d = day.
(POS. 2.3) Measure unit and decimal places number
[Tot.MU=dm³ X.XXX]
Setting the measure unit and decimals places number displayed for the volumes. To set the
measure unit, position the cursor on the measure unit field. To set the unit type, position the cursor
on the blank space between the measure unit and the numeric value; the decimal places number
can be selected by placing the cursor on numeric field and choosing one of the possible
combinations: 1000-01.00-001.0-00001.
(POS. 2.4-5) Pulse value channel 1-2 and total measure unit
[Pls1-2=dm³ X.XXXXX]
Setting of a flow volume by which a corresponding pulse will be emitted on channel 1-2, units must
be identical to ‘Full scale’ and ‘Totalizer’ functions. To set the parameter, complete the three fields,
from left to right: 1) measure unit, 2) unit type and 3) numeric value. The selection is performed by
positioning the cursor in the field to be modified. To change the unit type (metric, British or
American, mass or volume) position the cursor on the blank space between the measure unit and
the numeric value. When the nominal diameter is set to zero it is possible to modify only the
numeric field since the measure unit stays at meters (m) or feet (ft). Only those units described
above are available to be selected. This function is active only if the pulse emission on channel is
enabled.
(POS. 2.6-7) Pulse duration channel 1-2
[Tpls1-2=ms XXXX.XX]
Setting of the pulse duration generated on channel 1-2. This value is expressed in milliseconds and
has to be between 0.4 and 9999.99. When the high frequency output is present, then the minimum
value can be set to a minimum of 0.04 milliseconds. ATTENTION: since the transmitter cannot
detect which device type is connected to the transmitter, the user must verify that the set pulse
duration is compatible with the external device processing such pulses. If, for example, an electro-
mechanical pulse counter is connected, one of two problems may occur; firstly, if the pulse is too
long the coils may burn out, secondly, if the pulse is too short, the counter may not be able to
function, with the possibility of causing damage to the output.
in
3
Cubic inch
Gal
American gallon
GAL
British gallon
ft
3
Cubic foot
Bbl
Standard barrel
BBL
Oil barrel
yd
3
Cubic yard
kgl
KAmerican gallon
KGL
KBritish gallon
cm
3
Cubic centimeter
ml
Milliliter
L
Liter
dm
3
Cubic decimeter
dal
Decalitre
hl
Hectolitre
m
3
Cubic meter
Oz
Ounce
Lb
Pound
Ton
Short tons
g
Gram
kg Kilogram
t
Ton