English, 6 basic functions, 1 display mode – Burkert Type 1094 User Manual
Page 26
24 - 1094_400
english
6.6
Basic Functions
Input
Selection
ENTER
Display (2-lines)
V4.1
Operator?
INIT
Evaluation
Fuel flow
ACT.
40,0
l/min
Vapor flow
ACT.
44,0
l/min
C-factor
ACT.
110
%
V/R-Ratio
ACT.
110
%
Corr. VR
ACT.
100
%
Vapor Vol
ACT.
24,0
litre
Delay
Pump
ACT.
2
sec
Warming up Pump
ACT.
2
min
Flow meterCalib.
ACT.
000
Pulser
Generator
ACT.
100
Imp/l
Nozzle
ACT.
000
Remark
Selecting the operator mode
Fuel flow up to 51 l/min
Vapor flow up to 90 l/min
Correction factor from the
certificate of the system
Recovery rate
(air-/fuel volume)
Correct Recovery rate
(HC-vapor-/fuel volume)
Vapor volume
Time delay of the pump
Warming up time of the
pump
before the self adaptation
Flow meter calibration factor
Value displayed on the flow
meter
Pulse rate
Nozzle (only with control
electronics Multiplex)
6.6.1 Display Mode
- Type 1062 (112 pages)
- Type 1050 (4 pages)
- Type 8750 (64 pages)
- Type 8750 (82 pages)
- Type 8681 (90 pages)
- Type 8681 (40 pages)
- Type 8798 (2 pages)
- Type 8791 (4 pages)
- Type 8798 (106 pages)
- Type 8792 (118 pages)
- Type 8791 (15 pages)
- Type 8792 (136 pages)
- Type 8792 (252 pages)
- Type 8718 (34 pages)
- Type 8791 (154 pages)
- Type 8791 (106 pages)
- Type 8791 (184 pages)
- Type 8791 (28 pages)
- Type 8791 (21 pages)
- Type 0911 (46 pages)
- Type 0911 (64 pages)
- Type 0911 (84 pages)
- Type 0911 (76 pages)
- Type 1058 (31 pages)
- Type 1060 (4 pages)
- Type 1066 (112 pages)
- Type 1067 (158 pages)
- Type 1077-2 (33 pages)
- Type 1094 (41 pages)
- Type 1094 (82 pages)
- Type 1094 (12 pages)
- Type 1115 (25 pages)
- Type 1150 (99 pages)
- Type 1541 (2 pages)
- Type 5142 (6 pages)
- Type 8619 (40 pages)
- Type 8619 (134 pages)
- Type 8620 (177 pages)
- Type 8622 (4 pages)
- Type 8623 (130 pages)
- Type 8623 (90 pages)
- Type 8625 (118 pages)
- Type 8624 (124 pages)
- Type 8718 (1 page)