background image

22

Serial Communication

Serial Communication

command number
command name

0x92
extSetpoint

request
Command

0x92

Byte count

5

data

1 byte
0

Internal set-point value settings

1

External set-point value settings

4 bytes
0 ... 3

Set-point value [%] (float)

8)

response
Command

0x92

Byte count

7

Status

2 bytes, device status

data

1 byte
0

Internal set-point value settings

1

External set-point value settings

4 bytes
0 ... 3

Set-point value [%] (float)

8)

Description

determines the set-point value settings and describes the external set-point value as a percentage:
Internal = analog - the set-point value settings is assigned by the analog set-point value signal that is

created

External = RS232, RS485

Command 0x92 - ExtSetpoint

Table 13:

First byte transferred: MSB

8)

english

Typ 8605