beautypg.com

Electrical connections, English – Burkert Type 6510 User Manual

Page 9

background image

6510/6511 - 9

T

ECHNICAL

D

ESCRIPTION

english

Electrical connections

NOTE

The pilot pressure of the pneumatic controller is dependent on the pressure of the flow
of medium: it must not exceed a maximum of 7 bar!

Observe the permissible pressure range given on the rating
plate!
Pressure difference between Ports 1 and 3/5

≥≥≥≥≥ 2,5 bar

ATTENTION!

Flying lead
connection

Round plug
connection M8

Square plug
connection

Figure: Connection variants for the pilot valve 6104

Pilot valve type 6104

• read the voltage, electrical power, type of protection and current from the rating plate!
• voltage tolerance ±10%
• with 100 % duty cycle and the max. ambient temperature, the coil heats up:

in a single valve assembly, up to approx. 105° C
in a block assembly to approx. 120° C

NOTE

Ensure a long service life for the pilot valve by using a 5µ filtration

ATTENTION!

Note the voltage used! With alternating current, always connect a rectifier into the
circuit!