Installation – Burkert Type 6203 User Manual
Page 4
12
Operating duration
Unless otherwise indicated on the type label, the solenoid
system is suitable for continuous operation.
Important information for functional reliability during
continuous operation!
For long switch-on or switch-off times a minimum
actuation of 1-2 switching operations per day is
recommended.
Service life
High switching frequency and high pressures reduce the
service life.
english
13
6.2. Type label
6203 A 10 EPDM MS
Made in Germany
00229009
W14 LU
230V 50Hz 8W
G3/8 P
N0
-
10bar
Type
Operating principle
Orifice
Seal material
Housing material
Identification number
Manufacturer code
Voltage, Frequency, Power
consumption
Connection thread, Nominal pressure
Fig. 1:
Location and description of the type label
english
14
7. insTallaTiOn
7.1. safety instructions
Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
• Before reaching into the system , switch off the power
supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
• Installation may only be carried out by authorized tech-
nicians with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
english
15
7.2. before installation
Installation position:
Installation can be in any position.
Preferably: Drive at the top.
→
Prior to installation check pipelines for dirt and if
required, clean.
Dirt filter: To ensure that the solenoid valve functions
reliably, a dirt filter (≤ 500 μm) must be installed in front of
the valve inlet.
7.3. installation
→
Hold the device with a suitable tool (open-end wrench)
on the housing and screw into the pipeline.
note!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
→
Observe direction of flow:
The arrow on the housing indicates the direction of
flow.
english
Type 6203 EV