Structure and function, Technical data – Burkert Type 6114 User Manual
Page 3
english
8
STRUCTURE AND FUNCTION
The flipper valve Type 6114 is a 3/2-way solenoid valve
which can be operated electrically (mono or bistable).
TECHNICAL DATA
Operating Conditions
WARNING!
Risk of injury due to malfunction.
Malfunction if used outside!
• Do not use Type 6114 outdoors and avoid heat sources
which may cause the permitted temperature range to
be exceeded.
Ambient temperature:
5 to +55 °C
Medium temperature:
5 to +55 °C FFKM
0 to +55 °C EPDM
Media:
Compressed air lubricated,
non-lubricated or dry;
neutral liquids and gases (5 µm filtration);
technical vacuum
Protection class: IP65
Protection class: 3 as per VDE 0580
english
9
Mechanical Data
Dimensions
See data sheet
Housing material
PPS, fibre-glass reinforced
Sealing material
EPDM / FFKM
WARNING!
Risk of injury from discharge of medium through
damaged seals.
Unsuitable medium may damage the sealing material
(brittleness, destruction, swelling).
• Use only media suitable for the sealing material.
• If you have any queries, please consult our staff.
english
10
Type label
Example: Precontrol for bistable tapware (pulse version)
Nominal width
Operating principle
Pressure range
Voltage (±10 %)
Type
Output
61
14 0,6 EPD
M
PN 0,5-10bar
D
6V Impuls 20ms 1W
XXXXXXXX W29LS
Order no.
Sealing material
english
11
Pneumatic Data
Operating principles D
B
P R
Precontrol for
tapware
3/2-way valve, direct-acting,
disconnected
output 2 pressurised
Fluid connections
1
P
Pressure connection
2
B
Working connection
3
R
Exhaust air connection
Pressure range
see type label
R seat
P seat
B
Type 6114