To prevent injury, ensure that:
• Do not supply the medium connectors of the system with aggressive

or flammable mediums.

• Do not make any external modifications to the device bodies. Ensure

that the system cannot be activated unintentionally.

• Installation and repair work may be carried out by authorized techni-

cians only and with the appropriate tools.

• After an interruption in the power supply or pneumatic supply, ensure

that the process is restarted in a defined or controlled manner.

• Do not put any loads on the body.
• Observe the general regulations of technology.

4.1. models with explosion protection

DAnGer!

Danger of explosion!
Improper use in the potentially explosive area may result in an
explosion.
• Also follow the specifications in the certificate of conformity.
• If models have ATEX approval, also follow the specifications in the

ATEX instructions.

5.

system descriptiOn

5.1. general description
The direct-acting solenoid valve Type 6013 is available in two designs:
• Type 6013 is used for the blocking, dosing, filling and venting of

neutral gaseous and liquid media.

• Type 6013A is used for the blocking, dosing, filling and venting and

particularly for analysis technology.

The modular designed valve can be installed individually or in a block
on the multiple manifold.

6.

technical data

6.1. conformity
In accordance with the EC Declaration of conformity, the solenoid valve
Type 6013 is compliant with the EC Directives.

6.2. standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.

english

6.3. Operating conditions

WArnInG!

Heat sources and temperature fluctuations may cause malfunc-
tions or leaks!
• If the device is used outdoors, do not expose it unprotected to the

weather conditions.

• Avoid heat sources which may cause the allowable temperature

range to be exceeded.

Medium temperature:

Operating

principles

Sealing material

Medium temperature

CFA

FKM

-10 ... +100 °C (PA Coil)

-10 ... +120 °C (Epoxide Coil)

PTFE/Graphite

-10 ... +180 °C

CFB

FKM

-10 ... +100 °C (AC)

-10 ... +120 °C (DC)

Ambient temperature:

-10 ... +55 °C

Viscosity:

21 mm/s

Protection class:

IP65 in accordance with EN 60529 with
cable plug

Media:

neutral gaseous and liquid media, which do not attack
body and sealing materials (see table of resistance under

www.burkert.com

)

Check resistance in individual cases

6.4. fluidic data

Operating principle

A

(NC)

1 (P)

2 (A)

2/2-way valve, normally closed

B

(NO)

1 (P)

2 (B)

2/2-way valve, normally open

Pressure range:

see type label

Line connectors:

Type 6013: G1/8, G1/4, G3/8, Flange
Type 6013A: G1/8, G1/4

Note the information specified on the type label for voltage,
type of current, and pressure.

english

6.5. type label

Ident. no.

Voltage, Frequency, Output

Nominal connection pressure

Type

Circuit function

Orifice

Sealing material

Body material

6013 A 2,0 FKM MS

Made in Germany

CE

00450000

WXXXX

24V 50Hz 7W

G1/8 PN 0

-

10 bar

6.6. electrical data
Connections:

DIN EN 175301-803 Form A
for cable plug Type 2508

Supply voltage:

Type 6013: 24 V DC ± 10 %
max. residual ripple 10 %
24 V / 50 Hz
230 V / 50 Hz

Type 6013A: 24 V DC ± 10 %
max. residual ripple 10 %
230 V / 50 Hz

Voltage tolerance:

± 10 %

Nominal output:

CFA: 8 W (5 W, 10 W)
CFB AC: 7 W (9 W)

DC: 8 W

Impulse version DC: 7 W

Nominal operating mode:

100 % continuous operation
for block installation:
5 W continuous operation
on request a. A.
8 W intermittent operation 60 %
(30 min)