beautypg.com

Burkert Type 6013 User Manual

Page 8

background image

8

Application conditions of the devices

5.2.

Operation only with associated
valve

The solenoid coils type AC10 - PD73 to AC10 - PD86 may be operated
as a complete device only with associated valve body which satisfies the
following requirements:
• Materials for individual and block assembly:

Metal (brass, aluminum, stainless steel) or plastic (e.g. polyamide
PA 6 GV).

DANGER!

Danger of explosion!
• If devices are used in gasoline pumps to control gasoline as

Category 2, a valve body made of metal (brass, aluminum or stain-

less steel) must be used.

Minimum dimensions of the valve bodies:
• 32 mm x 32 mm x 10 mm (L x B x H)

A larger valve body with better heat conductivity may be attached
at any time.

5.3.

Individual assembly

The solenoid coils type AC10 - PD47 to AC - PD72 are suitable for
individual assembly only.

5.4.

Operating temperature range

For each type observe the operating temperature range specified in
the Electrical Data.

5.5.

Ambient temperature > 55 °C

In the case of solenoid coils type AC10 - 6 - PD53 and AC10 - 6 -
PD66 for an ambient temperature > 55 °C a heat-resistant cable is
used.

5.6.

Application in petrol pumps

DANGER!

Risk of explosion by opening the device!
• The device is a closed system. It must not be removed!
Danger of explosion!
• If devices are used in gasoline pumps to control gasoline as

Category 2, a valve body made of metal (brass, aluminum or

stainless steel) must be used.

The solenoid coils type AC10 may also be used to control gasoline
in Category 2 if there is no air and no oxygen in the closed system.
This also applies to starting and switching off the system.

• The coil is mounted on the core guide pipe.
• The valves always represent a closed system.

The solenoid coils may be removed by the manufacturer
only!

english

PTB 00 ATEX 2129 X