8 electrical control unit, 9 malfunctions, 8electrical control unit – Burkert Type 2731 User Manual
Page 24: 9malfunctions

8
elecTrical cOnTrOl uniT
The valve Type 2730 / 2731 / 2731K can be combined with fol-
lowing control units:
• Type 8630
Positioner TopControl Continuous
• Type 8635
Positioner SideControl
• Type 8692
Positioner TopControl
• Type 8694
Positioner TopControl Basic
• Type 8792
Positioner SideControl
• Type 8693
Process controller TopControl
• Type 8793
Process controller SideControl
Follow instructions for use in the Ex area!
See chapter “3.1”
The electrical connection of the control unit is described in
the respective operating instructions for the control unit.
9
MalfuncTiOns
malfunction
cause /remedial action
Actuator does
not switch
Pilot air port interchanged
4)
CFA:
Connecting lower pilot air port
CFB:
Connecting upper pilot air port
Pilot pressure too low
See pressure specifications on the type label.
Medium pressure too high
See pressure specifications on the type label.
Valve is not
sealed
Medium pressure too high
See pressure specifications on the type label.
Pilot pressure too low
See pressure specifications on the type label.
Flow rate
reduced
PTFE diaphragm bulging
→
Replace diaphragm.
Tab. 12: Malfunctions
4)
see “Fig. 19: Pneumatic connection”
24
Electricalcontrolunit
english
Type 2730 / 2731 / 2731K