beautypg.com

2 replacing the diaphragm – Burkert Type 2037 User Manual

Page 23

background image

23

Repairs

11.2 replacing the diaphragm

Danger!

risk of injury from discharge of medium (acid, alkali, hot media)!
It is dangerous to remove the device under pressure due to the
sudden release of pressure or discharge of medium.

▶ Before removing a device, switch off the pressure and vent the lines.

▶ Completely drain the lines.

Disassembly and installation see “8.3.1 Devices with welded

body”.

required spare part
• Diaphragm

fastening types

orifice

(diaphragm size)

dn [mm]

fastening types for diaphragms

ptfE

EpdM / fkM

65

Diaphragm with

bayonet catch

Diaphragm
screwed in

80

100

Tab. 8: Fastening types for diaphragms

Upper control air connection
(for CFB and CFI)

Lower control air connection
(for CFA and CFI)

Mark tab for direction
of flow

Diaphragm

Body

4 fastening screws

Example:

Fig. 19: Replacement of diaphragm

english

Type 2030, 2031, 2031 K, 2032,

2033, 2037

This manual is related to the following products: