11 replacement parts, 1 replacement part sets – Burkert Type 2012 User Manual
Page 18
18
Replacementparts
Type 2012
10
malfuncTiOns
malfunction
reason
remedial action
Actuator
does not
switch
Pilot air port
interchanged
→
Connect lower (CFA,
CFI) or upper (CFB,
CFI) control air
connection
Pilot pressure too low
→
Observe pressure
specifications on the
type label
Medium pressure too
high
Flow direction reversed
→
Observe direction
arrow on the body
Valve is not
sealed
Dirt between seal and
valve seat
→
Installing dirt trap
Seat seal worn
→
Installing new seat seal
Flow direction reversed
→
Observe direction
arrow on the type label
Medium pressure too
high
→
Observe pressure
specifications on the
type label
Pilot pressure too low
Valve is
leaking on
the release
bore
Packing gland worn
→
Renew packing gland
or replace actuator
Tab. 3: Malfunctions
11
replacemenT parTs
Caution!
risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable replacement parts may cause
injuries and damage the device and the surrounding area.
▶ Use only original accessories and original replacement parts from
Bürkert.
11.1 replacement part sets
The following spare part sets are available for the globe control valve
Type 2012:
• Seal set packing gland,
• Valve set (seal material PTFE),
• Valve fittings (seal material PTFE),
• Seal set swivel plate.
11.1.1 seal set packing gland
Contain: packing gland and graphite seal
actuator size
nominal diameter
Order number
175
65
155 483
175, 225
80
155 484
175, 225
100
155 485
english