Replacementparts

Type 2012

10

malfuncTiOns

malfunction

reason

remedial action

Actuator
does not
switch

Pilot air port
interchanged

Connect lower (CFA,
CFI) or upper (CFB,
CFI) control air
connection

Pilot pressure too low

Observe pressure
specifications on the
type label

Medium pressure too
high
Flow direction reversed

Observe direction
arrow on the body

Valve is not
sealed

Dirt between seal and
valve seat

Installing dirt trap

Seat seal worn

Installing new seat seal

Flow direction reversed

Observe direction
arrow on the type label

Medium pressure too
high

Observe pressure
specifications on the
type label

Pilot pressure too low

Valve is
leaking on
the release
bore

Packing gland worn

Renew packing gland
or replace actuator

Tab. 3: Malfunctions

11

replacemenT parTs

Caution!

risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable replacement parts may cause
injuries and damage the device and the surrounding area.

▶ Use only original accessories and original replacement parts from

Bürkert.

11.1 replacement part sets

The following spare part sets are available for the globe control valve
Type 2012:
• Seal set packing gland,
• Valve set (seal material PTFE),
• Valve fittings (seal material PTFE),
• Seal set swivel plate.

11.1.1 seal set packing gland

Contain: packing gland and graphite seal

actuator size

nominal diameter

Order number

175

65

155 483

175, 225

80

155 484

175, 225

100

155 485