beautypg.com

Technical data – Burkert Type 2000 User Manual

Page 4

background image

4

Technical data

Type 2000 INOX

To prevent injuries:
• Supply only media to the media connections which have been

specified as flow media in the chapter „Technical Data“.

• Do not use the Type 2000 INOX in potentially explosive areas.
• Do not physically stress the housing (e.g. by placing objects on

it or standing on it).

• Ensure that the system cannot be activated unintentionally.
• Only trained technicians may perform installation and mainte-

nance work.

• After an interruption in the power supply or pneumatic supply,

ensure that the process is restarted in a defined or controlled

manner.

• The device may be operated only when in perfect condition and

in consideration of the operating instructions.

• The general rules of technology apply to application planning

and operation of the device.

5. TECHNICAL DATA

5.1. Conformity

The angle seat valve, Type 2000 INOX, conforms to the EC Directives
according to the EC Declaration of Conformity.

5.2. Standards

The applied standards, which are used to demonstrate compliance
with the EC Directives, are listed in the EC type test certificate and/or
the EC Declaration of Conformity.

5.3. General technical data

Control functions: A (CFA) / B (CFB)
CFA: Closed in rest position by spring force.
CFB: Open in rest position by spring force.
Materials and connections: see data sheet

Installation position: Any position, preferably with the actuator

face up.

Inscription of the type label:

Flow 1 2
2000 A 10,0 PTFE VA

Made in German

y

00182076

W1X LU

G3/8 P

med 16 bar

Pilot 5,5 - 10 bar

Direction of flow: 1 and 2 = identification of the
connections on the valve housing

Seal material
Housing material

Identification number

Manufacturer code

Permitted control pressure range

Permitted max. medium pressure

Operating

principle

Type

Connection type

Orifice

english