beautypg.com

2 technical data for the type 6013 and 6022 units, English – Burkert Type 6022 User Manual

Page 16

background image

16 - 03 ATEX5014 X

english

3.2 Technical data for the type 6013 and 6022 units

Temperature class T3
Electromagnet
used

Type AC10, PTB 00 ATEX 2129X

Circuit function of
the valve

A = normally closed

Type of current

Universal current (0 Hz ... 60 Hz)

Rated voltage

12 V ... 400 V (±10 %)

Rated current

Coil size 5

Coil size 6

0,68 ...0,02 A

0,8 ... 0,02 A

Power limit at
steady state

Coil size 5

Coil size 6

7 W

9 W

Maximal permis-
sible ambient tem-
perature range
Single mounting

Coil size 5

Coil size 6

PD47: -30 °C ... +60 °C
PD60: -40 °C ... +60 °C

PD53: -30 °C ... +60 °C
PD66: -40 °C ... +60 °C

Type of protection IP 65 according to EN 60529 (DIN VDE 0470 Part 1)

Electrical connec-
tion

Electrical connection variants according to approval
of the type AC 10 electro-magnets PTB 00 ATEX
2129X (see following description).

Type of protection
/ Marking of the
magnetic coil

The type of protection changes depending on the
electrical connection variants (the components used):
II 2G Ex m II T4, T5, T6 or
II 2G Ex em II T4, T5, T6 or
II 2D Ex tD A21 IP65 T -40/-30 °C ...
(see following description).

Type of protection
/ Marking of the
complete unit

The marking changes depending on the electrical
connection variants (the components used):
II 1 / 2 G Ex m II T3 or II 1 / 2 G Ex em II T3
(see following description).

NOTES!

Only individual mounting is permissible for units of the types 6013 and
6022.