beautypg.com

1 technical data for the type 0641 and 2832 units, English – Burkert Type 6022 User Manual

Page 14

background image

14 - 03 ATEX5014 X

english

3.1 Technical data for the type 0641 and 2832 units

Temperature class

T3

Electromagnet used

Type 64.-, PTB 02 ATEX 2094X

Circuit function of the valve

A = normally closed

Type of current

Universal current (0 Hz ... 60 Hz)

Rated voltage

12 V ... 240 V (±10 %)

Rated current

0.58 ...0.034 A

Power limit at steady state

7 W

Maximal permissible ambient
temperature range

Individually mounted -40 °C ... +60 °C
Block assembly -40 °C ... +45 °C

Type of protection

IP 65 according to EN 60529
(DIN VDE 0470 Part 1)

Electrical connection

For the marking of the electrical connection
variants, the letters A, L and K are used
according to the Approval for Electro-
magnets PTB 02 ATEX 2094X
(see following description).

Type of protection / Marking
of the magnetic coil

Electrical connection "A":
II 2G Ex mb II T4, T5
Electrical connection "L" and "K":
II 2G Ex mb e II T4, T5
(see following description)

Type of protection / Marking
of the complete unit

Electrical connection "A ":
II 1 / 2 G Ex m II T3
Electrical connection "L" and "K":
II 1 / 2G Ex em II T3
(see following description)

This manual is related to the following products: