beautypg.com

X85 pallet – FlexLink X85 Туннельный модуль XBUL 11T Руководство пользователя User Manual

Page 8

background image

X85 Pallet

Sensor details

Sensor B1 ”Pre-stop”

Type: Proximity switch, inductive

Position: Placed together with Pre-stop.
Function: Detects the initiator plate of the pallet before the
pallet is stopped and stays active until the pallet leaves
the stop.

The reason why the pallet is detected by the sensor
before the pallet hits the stop, is to enchance the
efficiency of the pallet flow. As the pallet is detected in
advance, the controller has time to take a decision
whether or not the pallet should be stopped. If if should
pass, the stop change state to ”Release flow” before the
pallet reach it.

Sensor B1

Sensor B2 ”In position”

Type: Proximity switch, inductive. Model depends on
pallet length.

Position: Depends on pallet length.

100/125/175: Inside process position, left side

225: Before process position, right side

Function: Detects the pallet initiator plate when the pallet
is stopped in the process position.

Sensor B2 (pallet length 100/125/175)

Sensor B2 (pallet length 225)