X85 pallet – FlexLink X85 Туннельный модуль XBUL 11T Руководство пользователя User Manual
Page 8

X85 Pallet
Sensor details
Sensor B1 ”Pre-stop”
Type: Proximity switch, inductive
Position: Placed together with Pre-stop.
Function: Detects the initiator plate of the pallet before the 
pallet is stopped and stays active until the pallet leaves 
the stop.
The reason why the pallet is detected by the sensor 
before the pallet hits the stop, is to enchance the 
efficiency of the pallet flow. As the pallet is detected in 
advance, the controller has time to take a decision 
whether or not the pallet should be stopped. If if should 
pass, the stop change state to ”Release flow” before the 
pallet reach it.
Sensor B1
Sensor B2 ”In position”
Type: Proximity switch, inductive. Model depends on 
pallet length.
Position: Depends on pallet length.
100/125/175: Inside process position, left side
225: Before process position, right side
Function: Detects the pallet initiator plate when the pallet 
is stopped in the process position.
Sensor B2 (pallet length 100/125/175)
Sensor B2 (pallet length 225)