Communication Concepts FM-1KW Broadcast Application Note User Manual
Page 2
![background image](/manuals/326606/2/background.png)
2
RF Reference Design Data
Freescale Semiconductor
MRFE6VP61K25H MRFE6VP61K25HS FM Broadcast
MEASUREMENTS
24
31
100
29
27
P
out
, OUTPUT POWER (WATTS)
Figure 2. Continuous Wave Performance Graph
with Low Pass Filter versus Output Power
25
200
400
600
800 900 1000
G
ps
,P
OWER
GAIN
(d
B)
f = 108 MHz
Air--Cooled, CW, 87.5--108 MHz, Low Pass Filter
30
28
26
η
D,
DRA
IN
EF
FI
CIE
NCY
(%
)
90
70
60
50
40
30
20
80
1200
98 MHz
87.5 MHz
108 MHz
98 MHz
87.5 MHz
300
500
700
1100
V
DD
= 50 V
I
DQ
= 200 mA
20
32
86
24
f, FREQUENCY (MHz)
Figure 3. Continuous Wave Performance Graph
with Low Pass Filter versus Frequency
88
92
96
100 102 104
G
ps
,P
OWER
GAIN
(d
B)
30
28
22
η
D,
DRA
IN
EF
FI
CIE
NCY
(%
)
90
70
60
50
40
30
80
110
90
94
98
106
P
out
= 1100 W
V
DD
= 50 V
I
DQ
= 200 mA
G
ps
η
D
26
108
G
ps
η
D
Air--Cooled, CW, 87.5--108 MHz, Low Pass Filter
Table 1. CW Drive--Up at 87.5 MHz
P
in
(W)
P
out
(W)
Gain
(dB)
IRL
(dB)
Eff
(%)
V
DD
(V)
I
DD
(A)
I
DQ
(1)
(A)
0.3
150
27.0
--6.1
33.6
50
8.9
0.2
0.5
314
28.0
--6.5
48.0
50
13.1
0.2
1.0
639
28.1
--8.1
65.8
50
19.4
0.2
1.5
844
27.5
--10.1
72.6
50
23.2
0.2
2.0
975
26.9
--11.9
76.1
50
25.6
0.2
2.5
1056
26.3
--13.0
78.1
50
27.0
0.2
3.0
1100
25.6
--13.3
79.1
50
27.8
0.2
3.5
1116
25.0
--13.6
79.2
50
28.2
0.2
Table 2. CW Drive--Up at 98 MHz
P
in
(W)
P
out
(W)
Gain
(dB)
IRL
(dB)
Eff
(%)
V
DD
(V)
I
DD
(A)
I
DQ
(1)
(A)
0.3
168
27.5
--11.0
36.8
50
9.1
0.2
0.5
343
28.4
--11.8
52.0
50
13.2
0.2
1.0
660
28.2
--14.9
68.5
50
19.3
0.2
1.5
864
27.6
--19.4
75.3
50
22.9
0.2
2.0
999
27.0
--22.4
78.7
50
25.4
0.2
2.5
1058
26.3
--22.0
80.1
50
26.4
0.2
3.0
1085
25.6
--22.0
80.2
50
27.0
0.2
3.5
1094
24.9
--22.6
80.4
50
27.2
0.2
Table 3. CW Drive--Up at 108 MHz
P
in
(W)
P
out
(W)
Gain
(dB)
IRL
(dB)
Eff
(%)
V
DD
(V)
I
DD
(A)
I
DQ
(1)
(A)
0.3
193
28.1
--14.2
40.9
50
9.4
0.2
0.5
377
28.8
--14.9
56.1
50
13.4
0.2
1.0
695
28.4
--15.6
72.9
50
19.1
0.2
1.5
881
27.7
--13.5
78.6
50
22.4
0.2
2.0
980
26.7
--14.1
79.2
50
22.9
0.2
2.5
1018
26.1
--12.2
81.6
50
24.9
0.2
3.0
1066
25.5
--11.8
82.4
50
25.9
0.2
3.5
1092
24.9
--11.8
82.7
50
26.4
0.2
1. I
DQ
is set by adjusting a variable gate--source voltage while maintaining a constant 50 volts at the drain.