Physical data, Model ucw/h module and compressor – ClimaCool UCW_H 30, 50, 70, 85 User Manual
Page 7

5
www.climacoolcorp.com
Physical Data
Model UCW/H Module and Compressor
30
50
70
85
Capacity (tons) ¹
31.7
51.5
67.2
82.8
kW/Ton
0.738
0.746
0.744
0.740
Full-Load EER
2
16.3
16.1
16.1
16.2
Refrigerant Circuits (quantity)
2
2
2
2
Compressor Type
Scroll
Scroll
Scroll
Scroll
Compressor Quantity
2
2
2
2
Compressor Nominal Hp (per circuit)
15
25
35
40
Refrigerant Charge (per circuit) R-410A (lbs)
15
32
34
40
Module Operating Weight w/Water (lbs)
3
1480
2200
2450
2855
Module Shipping Weight (lbs)
4
1290
1880
2130
2390
30
50
70
85
Heat Exchanger (type)
Brazed Plate
Brazed Plate
Brazed Plate
Brazed Plate
Independent Refrigerant Circuits (quantity)
2
2
2
2
Water Storage Volume HX Only (gals)
3.2
6.1
7.3
11.4
Water Storage Volume HX Plus Main Headers (gals)
13.1
16.7
17.9
26.2
Min
30
50
70
85
Max
165
250
250
485
Maximum Design Working Pressure - Water Side (psi)
300
300
300
300
Header Water Connections - Inlet/Outlet (inches)
6
6
6
6
8
30
50
70
85
Heat Exchanger (type)
Brazed Plate
Brazed Plate
Brazed Plate
Brazed Plate
Independent Refrigerant Circuits (quantity)
2
2
2
2
Water Storage Volume HX Only (gals)
2.8
5.1
6.5
9.7
Water Storage Volume HX Plus 6" Main Headers (gals)
12.8
15.7
17.1
24.5
Min
40
65
85
100
Max
165
250
250
350
System Volume (gals)
8
Min
180
300
420
510
Maximum Design Working Pressure - Water Side (psi)
300
300
300
300
Header Water Connections - Inlet/Outlet (inches)
6
6
6
6
8
Notes:
1.
2.
3.
4. Unit shipping weight includes refrigerant charge, compressor oil and packaging.
5.
6.
7.
8. Required to provide stable operation. Storage/buffer tanks in return piping may be utilized to meet the minimum volume requirements.
Main header water/fluid connections are 6" grooved coupling for the 30, 50 and 70 ton modules. The 85 ton module uses 8" grooved couplings.
85 ton module cannot be directly coupled with 30, 50 or 70 ton modules due to a difference in header and frame size.
Module operational weight includes water, compressor oil, and refrigerant charge. Multiply times the number of modules for a total system
operational weight.
Tonnage ratings conditions: 44°F leaving chilled water temperature, 85°F entering condenser water temperature, flow rates are 3 gpm per ton
through the condenser with a fouling factor of .00025 hr-ft2-°F/Btu and 2.4 gpm per ton through the evaporator with a .0001 hr-ft2-°F/Btu fouling
factor.
Ratings in accordance with AHRI Standard 550/590.
The minimum/maximum flow rates are based on an approximate temperature differential of 5°F to 20°F through the evaporator and 5°F to 30°F
through the condenser. Flow rates vary based on application; verify with selection software.
Model UCW/H Condenser
Flow Rate (gpm)
5
Model UCW/H Evaporator
Flow Rate (gpm)
5