beautypg.com

Fe fi – CEMB USA C71_2 evo (D) User Manual

Page 9

background image

I 0637 -

9

6

FE

FI

GB

5.2.1.1 - Static & combined modes

After calibration as per

STEEL OR ALUMINUM WHEEL RIMS. SPRUNG COUNTERWEIGHTS

, it is possible to modify the

position of the correction weights using the

buttons.

STATIC: Select by pressing

(5E)

Balancing of light alloy rims with application of adhesive weights
on the shoulders of the rims.

Combined balancing: adhesive weight on the outside and clip-on
weight on the inside.

Combined balancing: adhesive weight on the inside and clip-on
weight on the outside.

5.2.2 - Rims with internal counterweight

Slide out the gauge on the LH side, at the point where a weight is to be fi tted. Wait for the “beep”. Slide it out further
towards the RH side and wait for a second “beep”. The wheel balancer automatically identifi es ALUS mode.

Counterweight position automatically suggested

.

(5I) can be used to set the alternative position indicated.

Adhesive
weights
position