CEMB USA C71_2 evo (D) User Manual
Page 16

I 0637 -
16
12
GB
6.4 - Display saver
It is possible to enable a screen saver function which temporarily replaces the data displayed with moving symbols.
This function acts when the balancing system is not used for the time period defi ned in the relative set-up:
►
Modify time expressed in minutes.
CONFIRM
If the value is set to 0, the display saver is automatically
disenabled. The display saver is not active in the balancing
machine set-up menu.To return to normal balancing machine
function, simply press any button or move the wheel.
6.5 - Automatic gauges calibration
6.5.1 - Rim distance gauge
►
►
Leave the distance gauge in rest position and press
(fi g. 12)
Bring the gauge in contact with the fl ange surface and press
(fi g. 13)
CORRECT CALIBRATION
Return the gauge to rest position.
The wheel balancer is ready for operation.
▪
▪
▪
▪
N.B.: In the event of errors or faulty operation, the writing “
P.0
” appears on the display : shift the gauge to
the rest position and repeat the calibration operation exactly as described above. If the error persists,
contact the Technical Service Department. In the event of incorrect input in the rim distance gauge calibra-
tion function, press
to cancel it.