7 - SPECIAL CALIBRATIONS AND FUNCTIONS
(See Access diagram)
In order to gain access to the “Reserved Calibrations and functions” it is necessary to enter a password.
Any incorrect operation within the functions described below could impair the operation of the wheel
balancing machine. Unauthorized use will cause cancellation of the warranty on the machine.
7.1 ENABLING OF WIDTH MEASUREMENT (OPTIONAL)
This function enables/disables automatic width measurement with SONAR or contact device: select “OFF”
under normal conditions and “SONAR” if the machine has provision for automatic width measurement.
7.2 - PRESETTING THE CUSTOMER AND USER NAME
The machine can be customized by presetting:
a) The name appearing on the Initial screen (screen-save).
b) The name of 4 different machine users ( USER NAME).
An “ideal” keyboard appears on the monitor with the set of characters available for composition of the
wordings.
The Customer’s name consists of three lines, each max. 30 characters.
The USER NAME consists of a wording max. 15 characters.
7.3 - ENABLING OF ECCENTRICITY MEASUREMENT (OPTION)
Enables/disables measurement of the tyre eccentricity during an unbalance measurement spin.
7.4 - CALIBRATIONS
When 6 is pressed from the Special Functions menu, access is gained to the Calibration menu.
7.4.1- GAUGE CALIBRATION
Select the gauge to be calibrated and follow the instructions appearing on the monitor.
N.B.:
- In the diameter gauge calibration it is highly important to position the gauge correctly as shown in figure 8.
- In the width gauge calibration it is necessary to enter two dimensions which can be measured as follows:
A -
GAUGE “ZERO” DISTANCE
SONAR “ZERO” DISTANCE
Fig. 12
B - DISTANCE FROM CALIBRATION POINT
Fig. 13