beautypg.com

A.O. Smith BFC - 28 User Manual

Page 82

background image

is

Release R

.1.3

UK

82

Wa

rn

in

g

Ma

intena

nce may

o

nly be pe

rformed

b

y a

qu

alifie

d se

rvi

ce and main

te

nance

e

ngin

eer

.

C03

(b

lo

ckin

g

err

o

r)

Reset error

.

To

o many re

se

ts

in

to

o

sh

ort a

pe

riod.

W

ai

t for the

error to

disa

ppea

r (ma

ximum 1 ho

ur).

If the e

rro

r does

no

t di

sa

ppe

ar

, th

e water heater

controll

er

mu

st be repl

aced.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

C04

(b

lo

ckin

g

err

o

r)

Appl

iance

sel

ection

error

.

Inco

rre

ct app

lia

nce

se

lection

/

Inco

rre

ct sele

ct

io

n

re

sistor

.

1.

C

heck whether the correct

a

ppli

ance ha

s

be

en sele

cte

d. See

’9

.5

D

ispla

y the

sele

cte

d a

ppl

iance

.

2.

If the

correct

appl

ian

ce

is

sel

ecte

d, fit the

corre

ct

selectio

n

res

istor

.

3.

If i

ncorrect a

ppli

ance

sele

ct

ed,

select the correct

one.

If the

e

rro

r do

es

not d

isapp

ear

, you

must

co

nt

act

you

r

in

st

al

ler

.

To

o

bt

a

in a sele

ctio

n re

sisto

r,

you must con

tact yo

ur inst

alle

r.

E01 (blo

cking

erro

r)

Th

e te

mp

erature

protection

at the

top

of

the t

a

nk

h

as been

activated.

The

te

mperature of th

e

water

a

t the to

p of

the

ta

n

k i

s

>

85°C.

No

ne.

T

his is a te

mp

orary me

ssa

ge that ma

y ap

pea

r from

time to

time, b

ut wi

ll

disa

ppea

r au

to

ma

tically

.

E03 (blo

cking

erro

r)

Error i

n

te

mp

erature

senso

r T

1

at the

to

p o

f

the t

a

nk.

T

he te

mp

er

at

ure

dif

ferentia

l b

etween

the

two

tempera

ture

se

nsors in

the

ta

nk is

>

10°C over a perio

d of

60 second

s

o

r lo

nger

.

1.

C

heck se

nsor positio

n and wiri

ng.

2.

R

eset

the T

hermoCo

ntro

l if

ne

cessary

. Rep

lace the senso

r if

th

e er

ror

p

e

rs

ist

s.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

E04 (blo

cking

erro

r)

Error in

the dummy

senso

r

(2)

.

The

two

du

mmy

se

nsors

detect

a

dif

ferentia

l o

f >

10°C

over

a p

eriod

o

f 60

se

conds or lon

ger

.

1.

C

heck

wiring

from dummy 1

an

d

dummy 2

.

2.

R

eset Th

ermoCon

trol

if ne

ce

ssary

. R

epla

ce the d

ummy sensor

if the error persist

s.

To

rep

lace

the du

mmy sensor you must

con

ta

ct your inst

all

er

.

1.

Te

mpera

tur

e sen

so

r

T

1

is

a ‘2 in 1’ sensor

,

T

1

cont

ai

ns

2

NTCs

fo

r t

he high-

limit

t

her

most

at

a

nd

sa

fet

y t

h

ermost

at

p

rot

ecti

on.

2.

The dummy se

nsor co

nsist

s

of

du

m

m

y se

ns

or

1

an

d

d

u

m

m

y se

ns

or

2

3.

The dummy se

nsor co

nsist

s

of

du

m

m

y se

ns

or

1

an

d

d

u

m

m

y se

ns

or

2

Ta

ble

10.2

Displ

ayed errors (Shee

t 10 of 10)

Co

de

+

De

scrip

tio

n

Po

ss

ib

le

c

aus

e

S

o

lu

tio

n

R

emar

k

This manual is related to the following products: