10 troubleshooting, 1 introduction, Troubleshooting – A.O. Smith BFC - 28 User Manual
Page 69: Introduction

Release R.1.3 UK
69
10
Troubleshooting
10.1 Introduction
A distinction is made between:
•
General errors
General errors are not reported on the display. General errors are:
-
Gas smell
-
Display does not light up
-
Insufficient or no hot water.
-
Water leakage
-
Explosive ignition
Table 10.1
gives a troubleshooting overview for general errors.
•
Displayed errors
Errors are reported on the display, as follows:
-
Line 1: An error code and its short description. The code is made up
of a letter and two digits.
-
Lines 2, 3 and 4: a long description, and a recommended action,
alternating every 2 seconds. See
Figure 10.1
and
Figure 10.2
.
The displayed errors are divided into two groups:
There are various types of errors:
-
LOCK OUT ERRORS
When the cause is no longer present, these errors require a reset with
the R button, before the appliance can resume running.
-
BLOCKING ERRORS
These errors disappear automatically once the cause of the error has
been removed, after which the appliance resumes by itself.
Table 10.2
gives a troubleshooting overview for the errors that appear on the
display.
n
Remark
Footnotes referred to from within any table are shown at the bottom of the
last page of that table.
S02: SENSOR ERROR
TOP TANK
SENSOR 1
NOT CONNECTED
Figure 10.1 Possible error
S02: SENSOR ERROR
TOP TANK
CHECK TOP TANK
SENSOR
Figure 10.2 Action
gis