UK

73

Wa

rn

in

g

Ma

intena

nce may

o

nly be pe

rformed

b

y a

qu

alifie

d se

rvi

ce and main

te

nance

e

ngin

eer

.

Ta

ble

10.2

Displ

ayed errors (Shee

t 1 of

1

0)

Co

de

+

De

scrip

tio

n

Po

ss

ib

le

c

aus

e

S

o

lu

tio

n

R

emar

k

S01 (blo

cking

erro

r)

Op

en circuit fro

m

temperature senso

r T

2

at

bo

ttom

o

f t

ank.

Se

nsor is not

(co

rre

ctly) conn

ecte

d.

Co

nnect th

e

se

nsor lead

to JP3.

Se

e appe

ndi

x

’A.2

Electrical di

agram BFC’

.

Damage

d wiring

o

r

defective sensor

.

Re

place

the

sen

so

r.

To

rep

lace

the

ne

ce

ssary

pa

rt

s, you mus

t

cont

act your inst

aller

.

S02 (blo

cking

erro

r)

Op

en circuit fro

m

senso

r 1 of

temperature senso

r T

1

at th

e top o

f the t

an

k

(1)

.

Se

nsor is not

(co

rre

ctly) conn

ecte

d.

Co

nnect th

e

se

nsor lead

to JP5.

Se

e appe

ndi

x

’A.2

Electrical di

agram BFC’

.

Damage

d wiring

o

r

defective sensor

.

Re

place

sen

sor T

1

.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

S03 (blo

cking

erro

r)

Op

en circuit fro

m

senso

r 2 of

temperature senso

r T

1

at th

e top o

f the t

an

k

(1)

.

Se

nsor is not

(co

rre

ctly) conn

ecte

d.

Co

nnect th

e

se

nsor lead

to JP5.

Se

e appe

ndi

x

’A.2

Electrical di

agram BFC’

.

Damage

d wiring

o

r

defective sensor

.

Re

place

sen

sor T

1

.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

S04 (blo

cking

erro

r)

Op

en circuit fro

m

dummy 1.

Dummy is not

(co

rre

ctly) conn

ecte

d.

Co

nnect

th

e d

ummy sen

sor l

ead

(2)

to JP4.

Se

e appe

ndi

x

’A.2

Electrical di

agram BFC’

.

Defecti

ve dummy

.

R

e

place

the du

mmy sensor

.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

S05 (blo

cking

erro

r)

Op

en circuit fro

m

dummy 2.

Dummy is not

(co

rre

ctly) conn

ecte

d.

Co

nnect

th

e d

ummy sen

sor l

ead

(3)

to JP4.

Se

e appe

ndi

x

’A.2

Electrical di

agram BFC’

.

Defecti

ve dummy

.

R

e

place

the du

mmy sensor

.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

S1

1 (bloc

king

e

rror)

Short c

irc

uit

from t

he

temp. sensor T

2

at th

e

bottom

o

f the t

a

nk.

Sh

ort

circui

t in the

se

nsor circuit.

Re

place

sen

sor T

2

.

To

rep

lace

the

ne

ce

ssary p

a

rt

s, yo

u mu

st

cont

act you

r in

st

al

ler

.

This manual is related to the following products: