Update rate summary, Motec appendices 59 – MoTeC ADL3 EDL3 User Manual
Page 63

MoTeC
Appendices
59
Update Rate Summary
Device
Input Type
Maximum Update
Rate (per second)
ADL3
Analogue Voltage Inputs
1000
ADL3
Analogue Temperature Inputs
1000
ADL3
Digital Inputs and Speed Inputs
100
ADL3
RS232 and CAN Communications
50 max *
ADL3 CAN
comms
fast
receive
1000
ACL RS232
Communications
200
*
ACL
General CAN communications
200 *
VIM
AV Fast Inputs
1000
VIM
AV Differential Voltage Inputs
1000
VIM
AV High Resolution Inputs
500
VIM
AV Special Inputs
1000
VIM Speed
Inputs
100
ADL2/SDL
Analogue Voltage Inputs 1 to 4
(ADL2/SDL) and 11 to 14 (ADL2)
1000
ADL2/SDL
Other Analogue Voltage Inputs
500
ADL2/SDL
Analogue Temperature Inputs
500
ADL2/SDL Lambda
Inputs
100
ADL2/SDL
Digital & Speed Inputs
100
SDL Internal
G
Sensors
100
E888 Thermocouple Inputs
(First Device / Second Device)
100 / 50
E888/816
Analogue Voltage & Digital Inputs
(First Device / Second Device)
200 / 50
* RS232 & General CAN Communications update rate depends on how
frequently the data is sent from the device. Typically the update rate from an
M4, M48, M8 or M800 ECU is about 20 times per second using RS232 and
about 50 times per second for the M800 using CAN.