Section 20: Commissioning Checklist
All items on checklist must be completed correctly to ensure the system
functions properly and reliably. Complete and Sign below.
□
Check that all cables, wires and connectors are connected securely in
accordance with Section 2 of the Installation Manual.
□
Check that the Lightning Protection and Proper Grounding is present in
accordance with Section 3 and 4 of the Installation Manual and per
Procedure for Proper Grounding to Minimize Risk of Lightning Damage
manual.
Operational Checks
A. Set system to Day mode.
1)
□
Pull out the interlock switch.
2)
□
Wait at least 2 minutes.
3)
□
Check RED Error LED (LED1) on Micro Board does NOT blink. If it
blinks
,
that indicates a fault, see Problem 2 and 3, in the Troubleshooting
Guide
.
4)
□
Check that the controller does not produce any alarm signals.
5)
□
If possible, visually check the Light Engine is flashing and operating
normally
.
B. Set system to RED Night mode.
1)
□
Check LED1 on Red Driver module (bottom left of cabinet) is on if steady
burning and blinking if flashing
.
2)
□
Check that the controller does not produce any alarm signals.
3)
□
If testing a white only system, set to White Night mode and repeat
step A
,
starting from step 2.
4)
□
If possible, visually check the Light Engine lights up.
I, ________________________
(Print Name)
, have completed all final checks listed
above and observed satisfactory results. No issues to report at this time.
__________________________________ ___________________________
Signature
Date
__________________________________ ___________________________
Installation Site Location (Site Number, City, State)
Company Name
ONCE COMPLETED, TEAR OFF AND TAPE INSIDE THE DOOR OF THE POWER SUPPLY!!