Page 20 of 25
Status
Status information can be read from the microcontroller board using the following
protocol:
Master transmission
Byte
Value
0
‘S’
1
‘R’
2
‘D’
Slave response
Byte
Value
0
‘S’
1
‘R’
2
‘D’
3
Product identification, should read 0x06 for the single level FAA strobe
4
Firmware version
5
Number of white LED drivers
6
Number of faulty strings on white driver 1, if present
7
Number of faulty strings on white driver 2, if present
8
Unused
9
Red driver status: 0 if good, 1 if current is low, 2 if current is high
10
Status array, bits defined as follows:
0) 1 if unit is locked to an external sync signal, 0 if not
1) 1 if unit is receiving a 1PPM signal, 0 if not
2:3) Current dimming mode: 0 indicates 100%, 1 indicates 30%, 2 or 3
indicates 10%
4) 1 if unit is in day mode, 0 if in night mode
5) 1 if unit is set for red night mode, 0 if set for white night mode
6) 1 if unit is set for normal night flash pattern, 0 if set for WRED night
flash pattern
7) 1 if red is in steady burning mode, 0 if in flashing mode
11
Red driver voltage control feedback level
12
Red driver current sense feedback
13
Red driver voltage control adjustment level
14
Fault monitor voltage in white driver 1
15
Fault monitor voltage in white driver 2
16
Unused
17
1 if white fault alarm is active, 0 if inactive
18
1 if red fault alarm is active, 0 if inactive
19:20 100ms interval timer value, in 4us increments. In 1PPM mode, this is
adjusted to match timing with the sync signal
21