Dialight SafeSite High Bay ATEX/IECEx User Manual
Operating instructions, High bay series led fixture for hazardous areas

Dialight - LED Solutions for Industrial and Hazardous Applications
Tel: +44 (0) 1638 665161 – Fax +44 (0) 1638 660718 –
www.dialight.com
High Bay Series LED fixture for
hazardous areas
Operating Instructions
Important Information:
These instructions contain safety information, read and follow them carefully. Dialight will not accept any
responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance.
Safety Instructions:
The installation, operation and maintenance must be
carried out by an electrician suitably trained in
hazardous areas with knowledge of increased safety
explosion protection IEC 60079-14
•
The technical data indicated on the LED fixture
are to be observed.
•
Changes of the design and modifications to the
LED fixture are not permitted
•
Repairs must only be carried out by a qualified
electrician with hazardous area knowledge.
•
Only genuine Dialight Replacement parts must
be used when unforeseen repairs are required.
•
Observe the national safety rules and
regulations during installation.
•
NO user serviceable Parts inside.
•
NO field replaceable parts.
Technical Data
Category of application EX d IIB T5 Gb
Ex tb IIIC T100°C Db
Ex II 2GD IP66
IECEx BAS 10.0074X
ATEX Baseefa10ATEX0148X
Rated Input Voltage: 100-277VAC 50/60Hz
Operating Temperature -40°C to +60°C
Input Voltage <200VAC -40°C to +50°C
Rated Input Power: 165 W MAX.
Housing Material: Copper Free Alu.
Housing Color: Wheel Grey
Storage Temp. -40°C to 60°C
Dimensions: See Figure 1
Protection Glass: Toughened Glass
Cable entries: N/A
Weight: 11.4 Kg (25 lbs)
A80-000864 Rev B