Parameter
Specification
Humidity
≤ 95% relative humidity, non-condensing
Altitude
≤ 2000 m
AC Input
*220 ACV ± 10%
,47~63 Hz
110 ACV ± 10%
,47~63 Hz
Operating temperature
0 – 40 ºC
Storage temperature
-10 – 60 ºC
*For 220V operation on models 8524 and 8526, please order model 8524-220V and 8526-220V
respectively.
Internal Resistances
The internal resistances of the DC load models are less than or equal to the following values:
Model
Internal
Resistance(mΩ
)
8500
≤ 35
8502
≤ 200
8510
≤ 15
8512
≤ 100
8514
≤ 8
8518
≤ 5
8520
≤ 45
8522
≤ 30
8524
≤ 6.5
8526
≤ 15
Operational power curve
The DC load's output follows a power curve illustrated below:
8500 DC Load Series
Version: 030614