Capacitance (6000 counts)

Range

Resolution

Accuracy

6 nF

0.001 nF

+(3.0% rdg + 30 dgt)

60 nF

0.01 nF

+(3.0% rdg + 10 dgt)

600 nF

0.1 nF

+(3.0% rdg + 10 dgt)

6 μF

0.001 μF

+(3.0% rdg + 10 dgt)

60 μF

0.01 μF

+(3.0% rdg + 10 dgt)

600 μF

0.1 μF

+(3.0% rdg + 10 dgt)

6 mF

1 μF

+(5.0% rdg + 10 dgt)

Overload protection: 600 V DC or 600 V AC RMS

Temperature

Range

Resolution

Accuracy

Sensor Type

-50°C - 0°C

0.1° C

+(2.0% rdg + 3°C)

K-type

Thermocouple

0°C -

400°C

0.1° C

+(1.0% rdg + 1°C)

400°C -

1300°C

0.1° C

+(2.0% rdg + 3°C)

-58°F -

32°F

0.1° F

+(2.0% rdg + 6°F)

32°F -

750°F

0.1° F

+(1.0% rdg + 2°F)

750°F -

2372°F

0.1° F

+(2.0% rdg + 6°F)

Overload protection: 30 V DC or 30 V AC RMS

% Duty Cycle

Range

Resolution

Accuracy (5V logic)

Pulse

Width

5% to 95%

0.1%

+(2.0% rdg + 10 dgt)

>10 μs

Frequency range:

5% to 95% (40 Hz to 1 kHz)

10% to 90% (1 kHz to 10 kHz)

20% to 80% (10 kHz to 20 kHz)

Overload protection: 600 V DC or 600 V AC RMS