Resistance, Continuity test, Diode test – B&K Precision 393 - Manual User Manual
Page 25: Conductance (6000 counts)
25
Resistance
Range
Resolution
Accuracy
Open Circuit
Voltage
600 Ω
0.01 Ω
+(0.3% rdg + 20 dgt)
-3.0 V DC typical
6 kΩ
0.1 Ω
+(0.3% rdg + 10 dgt)
-1.2 V DC typical
60 kΩ
1 Ω
+(0.3% rdg + 10 dgt)
-1.2 V DC typical
600 kΩ
10 Ω
+(0.3% rdg + 10 dgt)
-1.2 V DC typical
6 MΩ
100 Ω
+(1.0% rdg + 10 dgt)
-1.2 V DC typical
60 MΩ
1 kΩ
+(3.0% rdg + 20 dgt)
-1.2 V DC typical
Overload protection: 600 V DC or 600 V AC RMS
Continuity Test
Range
Audible
Threshold
Response
Time
Open Circuit
Voltage
600 Ω
<40 Ω
Approximately 100 ms -3.0 V DC typical
Overload protection: 600 V DC or 600 V AC RMS
Diode Test
Range/
Resolution
Test
Current
Accuracy
Open Circuit
Voltage
2 V / 1 mV
0.5 mA
typical
+(2.0% rdg + 10dgt)
3.0 V DC typical
Audible indication: Less than 0.05 V DC
Overload protection: 600 V DC or 600 V AC RMS
Conductance (6000 counts)
Range
Resolution
Accuracy
Open Circuit
Voltage
60 nS
0.01 nS
+(1.0% rdg + 10 dgt) -0.7 V DC typical
Equivalent resistance range: 16.7 MΩ to 100 GΩ
(S = Siemens = 1 / Ω )
Overload protection: 600 V DC or 600 V AC RMS