24

Current

DC Current

Range

Resolution

Accuracy

600 μA

0.01 μA

+(0.5% rdg +10 dgt)

6000 μA

0.1 μA

60 mA

1 μA

400 mA

10 μA

+(1.0% rdg + 10 dgt)

20 A

1 mA

+(2.0% rdg + 10 dgt)

AC Current (True RMS)

Range

Resolution

Accuracy (45 Hz - 1

kHz)

600 μA

0.01 μA

+(1.5% rdg + 20 dgt)

6000 μA

0.1 μA

60 mA

1 μA

400 mA

10 μA

20 A

1 mA

+(2.5% rdg + 20 dgt)

AC+DC Current (True RMS)

Range

Resolution

Accuracy (45 Hz - 1

kHz)

600 μA

0.01 μA

+(2.0% rdg + 30 dgt)

6000 μA

0.1 μA

60 mA

1 μA

400 mA

10 μA

20 A

1 mA

+(3.0% rdg + 30 dgt)

Burden Voltage:

500 mV on 600 μA & 60 mA ranges

2 V on 6000 μA, 400 mA, 20 A ranges

Input protection:

0.5 A/1000 V fast blow ceramic fuse (6.3x32mm) on μA/mA

input.

20 A/600 V fast blow ceramic fuse (10x38mm) on 20 A input.

20 A Input: >10 A for 30 sec. max, then a 10 min. cooling period.

Crest factor: 3 at full scale and 6 at half scale

AC Coupled True RMS specified from 2% to 100% of range

Peak hold accuracy: +(3.5% rdg + 500 dgt) at 45 Hz to 500 Hz on

AC current ranges