4 specifications, 4specifications, Voltage – B&K Precision 393 - Manual User Manual
Page 22
22
4
Specifications
Display: 60000 counts, 60 segments analog bar graph
Polarity: Automatic, (-) negative polarity indication
Overrange Indication: (OL) or (-OL) is displayed
Low Battery Indication: Indicates current capacity of battery.
When BATTERY is fully depleted, the display will show " bAtt "
with a continuous beep sound. The meter then shuts down in
5 seconds and no further measurement is allowed.
Measurement Rate: 2 measurements/sec nominal, 20
measurements/sec for analog bar graph
Operating Environment: 0°C to 50°C at < 70% R.H
Storage Environment: -20°C to 60°C at < 80% R.H
Temperature Coefficient: 0.1 × (specified accuracy) Per °C.
(0°C to 18°C, 28°C or 50°C)
Auto Power Off: Approx. 30 minutes
Altitude: 6561.7 ft (2000 m)
Power: single 9V battery
Battery Life: 50 hours typical with alkaline
Size (H × W × D): 7.8 Ч 3.6 Ч 1.7 inches (198 Ч 90 Ч 44 mm)
Weight: Approx. 14.1 oz. / 400 grams (including battery)
Accuracy is given as ± (% of reading + number of least
significant digits) at 18°C to 28°C, with relative humidity up to
70%.
Voltage
DC Volts
RANGE
RESOLUTION
Accuracy
Input Impedance
600 mV
0.01 mV
+(0.08% rdg +
5 dgt)
10 MΩ
6 V
0.1 mV
11 MΩ
60 V
1 mV
10 MΩ
600 V
10 mV
10 MΩ
1000 V
100 mV
10 MΩ
Overload protection: 1000 V DC or 750 V AC RMS