Arbitrary Waveform Generator — AWG7102 • AWG7101 • AWG7052 • AWG7051

Characteristics

Arbitrary Waveforms

Characteristic

AWG7102

AWG7101

AWG7052

AWG7051

Waveform Length

2 to 32,400,000 points (or 2

to 64,800,000 points, Option

01) in multiples of 64

Interleave:

2 to 64,800,000 points (or 2

to 129,600,000 points, Option

01) in multiples of 128

2 to 32,400,000 points (or 2 to 64,800,000 points, Option 01) in multiples of 64

Number of Waveforms

1 to 16,000

Sequence Length

1 to 4,000 steps

Sequence Repeat Counter

1 to 65,536 or infinite

Sequence Control

Repeat count, Wait for Trigger, Go-to-N, and Jump

Jump Mode

Synchronous and Asynchronous

Run Modes

Continuous

Waveform is iteratively output. If a sequence is defined, the sequence order and repeat functions are applied

Triggered

Waveform is output only once when an external, internal, GPIB, LAN, or manual trigger is received

Gated

Waveform begins output when gate is true and resets to beginning when false

Sequence

Waveform is output as defined by the sequence

Interleave operation

Up to 20 GS/s sample rate

(Option 06)

N/A

Clock Generator

Sampling frequency

10 MS/s to 10 GS/s

(10 GS/s to 20 GS/s at interleave)

10 MS/s to 10 GS/s

10 MS/s to 5 GS/s

Resolution

8 digits

Internal Clock

Accuracy

Within ±(1 ppm + Aging)

Aging: within ±1 ppm/year

Clock phase noise

< -90 dBc/Hz at 100 kHz offset

Internal Trigger Generator

Internal Trigger Rate

Range

1.0 μs to 10.0 s

Resolution

3 digits, 0.1 μs minimum

Skew Control Between Outputs

Range

-100 ps to +100 ps

N/A

-100 ps to +100 ps

N/A

Resolution

1 ps

N/A

1 ps

N/A

Skew accuracy

±(10% of setting +10 ps)

N/A

±(10% of setting +10 ps)

N/A

www.tektronix.com

5