beautypg.com

R&s fsh3, r&s fsh6, r&s fsh18 data sheet, Measurement uncertainty with scalar measurements – Atec Rohde-Schwarz-FSH3-6-18 User Manual

Page 19

background image

R&S FSH3, R&S FSH6, R&S FSH18

Data Sheet

1145.5973.12

TI.19

E-14

-3

-2

-1

0

1

2

3

0

2

4

6

8

10

12

14

16

18

20

Return Loss DUT / dB

M

ea

sur

em

ent

U

nc

er

tai

nt

y /

d

B

Measurement uncertainty with scalar
measurements

-3

-2

-1

0

1

2

3

0

5

10

15

20

25

30

Return Loss DUT / dB

M

e

as

u

rem

ent

U

nc

er

tai

nt

y /

d

B

Measurement uncertainty with vector
measurements (option R&S FSH-K2)

Specification

Condition

R&S FSH3

R&S FSH6

Phase measurements (transmission, reflection)
(only with R&S FSH3 models 1145.5850.13 or 1145.5850.23, R&S FSH6 1145.5850.26 and R&S FSH-K2)

Frequency range

Reflection
Transmission

with R&S FSH-Z2/-Z3

10 MHz to 3 GHz

5 MHz to 3 GHz

10 MHz to 6 GHz

5 MHz to 6 GHz

Display range

± 180° (wrap)

0° to 54360° (unwrap)

Group delay measurements
(only with R&S FSH3 models 1145.5850.13 or 1145.5850.23, R&S FSH6 1145.5850.26 and R&S FSH-K2)

Frequency range

Reflection
Transmission

with R&S FSH-Z2/-Z3

10 MHz to 3 GHz

5 MHz to 3 GHz

10 MHz to 6 GHz

5 MHz to 6 GHz

Aperture increments

1 to 300

Display range

10 ns, 20 ns, 50 ns, 100 ns, 200 ns, 500 ns,

1000 ns,

selectable