beautypg.com

Specifications – Atec Kikusui-PLZ-4W Series User Manual

Page 9

background image

9

P L Z - 4 W S E R I E S

[rating]

*1

The minimum operating voltage

(including the voltage drop due
t o t h e w i r e i n d u c t a n c e
component) in switching mode
increases by 0.15 V per 1 A/

μs

at slew rate settings greater than
5 A/

μs.

*2

The minimum operating voltage

(including the voltage drop due
t o t h e w i r e i n d u c t a n c e
component) in switching mode
increases by 0.3 V per 1 A/

μs at

slew rate settings greater than 5
A/

μs.

*3

Minimum voltage at which the

current star ts flowing to the
PLZ-4W. (The PLZ-4W detects
no signal at an input voltage less
than or equal to approximately
0.3 V and an input current less
than or equal to approximately 1
% of the range rating. Therefore,
if the input voltage is gradually
increased from 0 V, no current
will flow until 0.3 V is exceeded.
Once a current greater than or
equal to 1 % of the range rating
starts flowing, the current can
flow at voltages less than equal
to 0.3 V.)

[CC mode]

*1

Full scale of H range

*2

Vin: Input terminal voltage of

Electronic Load

*3

When the input voltage is varied

from 1.5 V to 150 V at a current
of rated power/150 V.

*4

M e a s u r e m e n t f r e q u e n c y

bandwidth: 10 Hz to 1 MHz

*5

M e a s u r e m e n t f r e q u e n c y

bandwidth: 10 Hz to 20 MHz

*6

At measurement current of 100 A

[CR mode]

*1

Conductance [S] = Input current [A]/

input voltage [V] = 1/resistance [

Ω]

*2

Conver ted value at the input

current. At the sensing point.

*3

set = Vin/Rset

*4

Full scale of H range

[CV mode]

*1

With respect to a change in the

current of 10 % to 100 % of the
rating at an input voltage of 1.5 V
(during remote sensing).

[CP mode]

*1

Full scale of H range

Rating

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operating voltage (DC)

1.5 V – 150 V

*

1

0 V – 150 V

*

2

Current

33 A

66 A

200 A

33 A

132 A

Power

165 W

330 W

1000 W

165 W

660 W

Minimum start voltage

*

3

0.3 V or greater

CC mode

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operating
range

Range

H

0 A – 33 A

0 A – 66 A

0 A – 200 A

0 A – 33 A

0 A – 132 A

M

0 A – 3.3 A

0 A – 6.6 A

0 A – 20 A

0 A – 3.3 A

0 A – 13.2 A

L

0 A – 330 mA

0 A – 660 mA

0 A – 2 A

0 A – 330 mA

0 A – 1.32 A

Setting range

Range

H

0 A – 34.65 A

0 A – 69.3 A

0 A – 210 A

0 A – 34.65 A

0 A – 138.6 A

M

0 A – 3.465 A

0 A – 6.93 A

0 A – 21 A

0 A – 3.465 A

0 A – 13.86 A

L

0 A – 346.5 mA

0 A – 693 mA

0 A – 2.1 A

0 A – 346.5 mA

0 A – 1.386 A

Resolution

Range

H

1 mA

2 mA

10 mA

1 mA

10 mA

M

0.1 mA

0.2 mA

1 mA

0.1 mA

1 mA

L

0.01 mA

0.02 mA

0.1 mA

0.01 mA

0.1 mA

Accuracy of
setting

Range

H, M

±(0.2 % of set + 0.1 % of f.s

*

1

) + Vin

*

2

/500 k

Ω

L

±(0.2 % of set + 0.1 % of f.s)

Input voltage
variation

*

3

Range

H

2 mA

4 mA

10 mA

2 mA

8 mA

M

2 mA

4 mA

10 mA

2 mA

8 mA

L

0.1 mA

0.2 mA

0.6 mA

0.1 mA

0.4 mA

Ripple

rms

*

4

3 mA

5 mA

20 mA

*

6

7.5 mA

30 mA

*

6

p-p

*

5

30 mA

50 mA

100 mA

*

6

50 mA

200 mA

*

6

CR mode

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operating
range

*

1

Range

H

22 S – 400

μS

(45.455 m

Ω – 2.5 kΩ)

44 S – 800

μS

(22.727 m

Ω – 1.25 kΩ)

133.332 S – 2.4 mS

(7.5 m

Ω – 416.666 Ω)

22 S – 400

μS

(45.455 m

Ω – 2.5 kΩ)

88 S – 1.6 mS

(11.363 m

Ω – 625 Ω)

M

2.2 S – 40

μS

(454.55 m

Ω – 25 kΩ)

4.4 S – 80

μS

(227.27 m

Ω – 12.5 kΩ)

13.3332 S – 2420

μS

(75 m

Ω – 4.1666 kΩ)

2.2 S – 40

μS

(454.55 m

Ω – 25 kΩ)

8.8 S – 160

μS

(113.63 m

Ω – 6.25 kΩ)

L

0.22 S – 4

μS

(4.545 5

Ω – 250 kΩ)

0.44 S – 8

μS

(2.272 7

Ω – 125 kΩ)

1.33332 S – 24

μS

(750 m

Ω – 41.666 kΩ)

0.22 S – 4

μS

(4.545 5

Ω – 250 kΩ)

0.88 S – 16

μS

(1.136 3 m

Ω – 62.5

k

Ω)

Setting range

Range

H

23.1 S – 0 S

(43.290 m

Ω – OPEN)

46.1 S – 0 S

(21.692 m

Ω – OPEN)

139.9968 S – 0 S

(7.1430 m

Ω – OPEN)

23.1 S – 0 S

(43.290 m

Ω – OPEN)

92.4 S – 0 S

(10.822 m

Ω – OPEN)

M

2.31 S – 0 S

(432.9 m

Ω – OPEN)

4.61 S – 0 S

(216.92 m

Ω – OPEN)

13.99968 S – 0 S

(71.430 m

Ω – OPEN)

2.31 S – 0 S

(432.9 m

Ω – OPEN)

9.24 S – 0 S

(108.22 m

Ω – OPEN)

L

0.231 S – 0 S
(4.329

Ω – OPEN)

0.461 S – 0 S

(2.1692

Ω – OPEN)

1.399968 S – 0 S

(714.30 m

Ω – OPEN)

0.231 S – 0 S
(4.329

Ω – OPEN)

0.924 S – 0 S

(1.0822

Ω – OPEN)

Resolution

Range

H

400

μS

800

μS

2.424 mS

400

μS

1.6 mS

M

40

μS

80

μS

242.4

μS

40

μS

160

μS

L

4

μS

8

μS

24.24

μS

4

μS

16

μS

Accuracy of
setting

*

2

Range

H, M

±(0.5 % of set

*

3

+ 0.5 % of f.s

*

4

) + Vin/500 k

Ω

L

±(0.5 % of set

*

3

+ 0.5 % of f.s)

CV mode

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operating
range

Range

H

1.5 V – 150 V

0 V – 150 V

L

1.5 V – 15 V

0 V – 15 V

Setting range

Range

H

0 V – 157.5 V

L

0 V – 15.75 V

Resolution

Range

H

10 mV

L

1 mV

Accuracy of setting

Range

H,L

±(0.1 % of set + 0.1 % of f.s)

Input current variation

*

1

12 mV

CP mode

Model

PLZ164W

PLZ334W

PLZ1004W

PLZ164WA

PLZ664WA

Operating
range

Range

H

16.5 W – 165 W

33 W – 330 W

100 W – 1000 W 16.5 W – 165 W

66 W – 660 W

M

1.65 W – 16.5 W

3.3 W – 33 W

10 W – 100 W

1.65 W – 16.5 W

6.6 W – 66 W

L

0.165 W – 1.65 W 0.33 W – 3.3 W

1 W – 10 W

0.165 W – 1.65 W 0.66 W – 6.6 W

Setting range

Range

H

0 W – 173.25 W

0 W – 346.5 W

0 W – 1050 W

0 W – 173.25 W

0 W – 693 W

M

0 W – 17.325 W

0 W – 34.65 W

0 W – 105 W

0 W – 17.325 W

0 W – 69.3 W

L

0 W – 1.7325 W

0 W – 3.465 W

0 W – 10.5 W

0 W – 1.732 5 W

0 W – 6.93 W

Resolution

Range

H

10 mW

10 mW

100 mW

10 mW

20 mW

M

1 mW

1 mW

10 mW

1 mW

2 mW

L

0.1 mW

0.1 mW

1 mW

0.1 mW

0.2 mW

Accuracy of
setting

Range

H, M

±(0.6 % of set + 1.4 % of f.s

*

1

)

L

±(0.6 % of set + 1.4 % of f.s)

Specifications

Unless specified otherwise, the specifications are for the following settings and conditions.

• The warm-up time is 30 minutes (with current flowing).

• After warm-up is complete, the PLZ-4W must be calibrated correctly according to the procedures given in the operation

manual in a 23 °C±5 °C environment.

• ** % of set denotes ** % of the input voltage, input current, or input power setting.

• ** % of f.s denotes ** % of the rated input voltage, rated input current, or rated input power.

• **% of rdg represents denotes ** % of the input voltage, input current, or input power reading.